Lingua Charging Case
overview
Figure 1-6 Lingua IR charging case
- LAN connection: two connections to daisy chain multiple charging cases and to configure the charging case and receiver settings using the web server.
- Two mains connectionsfor loop through. You can daisy chain up to three charging cases when using 125V or maximum of six for 230V.
- Status LED: shows the status of the CoCon charging case.
- Reset button: different reset options are available see "Reset the CoCon Charging Case" on page 1 for more information.
- Receiver slot: positions in the case to charge and update CoCon receivers.
- Receiver LED: indicates the status of the receiver.
You can use multiple charging cases in one setup. Simply connect the different charging cases using the LAN connection provided on the case.
Charging case status LED meaning
| Green |
Normal operating system |
| Blinking blue |
Updating receivers or charging case |
|
Red
|
Indicates an error
|
|
Yellow
|
fallback mode
|
charging case receiver LED meaning
| Blinking green |
The receiver is charging |
| Green |
The receiver is fully charged and functional |
| Blue |
Indicates the receiver is updating |
| Red |
Indicates that there is something wrong with the receiver, go to the receiver web server to see the type of error. |
Reset the CoCon Charging Case
There is a reset button on the charging case that allows you to reset specific settings depending on the reset procedure you perform:
reset network settings:
When the status LED is green (after power-up), you can reset the network settings back to 192.168.0.150 with subnet mask 255.255.255.0. Press and hold the reset button until the status LED changes to red (approximately 10 seconds). After you release the reset button, the charging case will reboot with the default network settings.
Factory reset
When you perform a factory reset you reset network settings and all configurations. Press and hold the reset button before switching on the power of the charging case. Hold the reset button until the status LED turns blue. Release the reset button to reboot the charging case in fallback mode.
In fallback mode, the web server will have reduced functionalities. You are only able to upload an update file. After reboot, the web server will have all functionalities again. Now, upload the update file again to complete the update process of the firmware. After the final reboot, you can create new configurations.